Lyophilised peptides arrive as a fragile white cake under vacuum. Reconstitution is the process of dissolving that cake into a known volume of sterile diluent so the researcher can measure a precise mass per unit volume.
Choice of diluent matters. Bacteriostatic water (sterile water with 0.9% benzyl alcohol) suppresses microbial growth in multi-use research vials and is the default for most peptides. Sterile water, normal saline and dilute acetic acid are used when a peptide is incompatible with benzyl alcohol or requires a specific pH to remain in solution.
The mechanical step matters as much as the chemistry. Inject diluent slowly down the inside wall of the vial — not directly onto the cake — and let it dissolve by gentle swirling. Shaking introduces shear forces that can fragment longer peptides and froths the solution with air bubbles that complicate later measurement.
The math is simple but easy to fumble. A 5 mg vial reconstituted in 2 mL of bacteriostatic water yields 2.5 mg/mL. To draw 250 µg, you draw 0.1 mL (10 units on a U-100 insulin syringe). Researchers should plan reconstitution volumes before opening the vial, write the resulting concentration on the cap, and date the vial — peptide solutions degrade much faster than their lyophilised parents.